PARTIAL DISCHARGE BEHAVIOUR OF TWO (OR MORE) ADJACENT CAVITIES IN POLYETHYLENE SAMPLES
Michael G. Danikas
In the present paper, the partial discharge behaviour of two
(or more) adjacent cavities in polyethylene samples is
investigated. The recorded discharge currents had very steep
rise times (in the range of ns). The question as to whether a
simultaneous breakdown occurs in both cavities or the breakdown
of one cavity causes the breakdown of the other(s) is discussed.
Keywords: partial discharge, enclosed cavities, rise time, apparent charge
|