CAPABILITY OF THREE-PHASE INDUCTION MOTOR ON CONTINUOUS SINGLE-PHASE OPERATION
Azza M. N. Abdel-Hamid
The 3-phase induction-motor may have to run 1-phase either accidentally or
deliberately. The object of this paper is to investigate continuous 1-phase running
near synchronous speed, including the derivation of the permissible currents and
the corresponding mechanical output, as compared with the original 3-phase design
ratings of the motor.
Keywords: 3-phase induction-motor, single-phasing, current and power ratings
|