DETECTION IMPROVEMENT OF THE BROKEN ROTOR BARS OF IM AFTER SUPPLY DISCONNECTION
Abdesselam Lebaroud - Amar Bentounsi
This paper presents some analysis techniques of the voltages induced in the
stator windings after supply disconnection, to detect broken rotor bars in
induction motor (IM). When the motor is disconnected from the supply voltage,
the broken bars cause a distortion of the magnetomotive force generated by rotor
windings, and some particular harmonics induced in the stator windings increase
their amplitude. The diagnostic technique is based on monitoring these voltage
harmonics via the non parametric estimation of the modified periodogram and
averaged periodogram. These techniques permit to evidence the principal harmonic
frequencies of the signal and decrease the noise influence, thus allowing a
better detection of the broken rotor bars.
Keywords: induction motor, detection, supply disconnection, broken bars
|