NUMERICAL MODELING OF ACCURACY OF AIR ION FIELD MEASUREMENT
Petr Drexler – Pavel Fiala – Karel Bartušek
An analysis of the electric state of air shows the presence of various ion sorts. The therapeutic effect of negative high-mobility ions of proper concentration is known. This positive effect was observed in caves that are used for speleotherapy. This article presents the capability of gerdien tube measurement methods for measuring ion concentration and present results obtained by the design of new type of gerdien tube.
Keywords: air ion, conductivity of air, gerdien tube
|