INFLUENCE OF WINDINGS LAYOUT ON MEASUREMENT ERROR OF SOFT MAGNETIC CORES
Mojmír Kollár – Ján Bydovský – Elemír Uák – Peter vec – Jozef Kuchta
This paper was aimed to estimate the possible measuring errors caused by a non-uniform lay-out and/or alignment of the magnetizing and sensing windings each made of only a few turns. Some theoretical considerations, 2D numerical solutions and also measurements on several types of samples are presented leading to a surprising conclusion how many turns at least are necessary for the primary (magnetizing) and the secondary (sensing) windings to provide a reasonable accuracy of testing or measurements.
Keywords: toroid cores, stray fields, lay-out and alignment of magnetizing and sensing windings, magnetization losses
|